1-800-Measure

Accredited Temperature & Speed Verification

Accredited Temperature & Speed Verification Services

This specialized service enhances our standard 10-point calibration by first verifying transducer performance against real-world environmental factors like heat and high speeds, ensuring your data is accurate under its true operating conditions.

Use our Torque Calculator!

Why Factory Calibration is Superior

As the original equipment manufacturer, we have an unmatched understanding of every transducer we build. Our unique position allows us to not only identify temperature-related effects but to correct them at the component level—a level of precision impossible for any third-party lab. You are not just getting a calibration; you are getting a factory-validated performance guarantee.

What is a 10-Point Calibration?

The foundation of our 10 point calibration services is the 10-point, bi-directional calibration. The transducer is loaded at ten distinct torque points in both increasing and decreasing directions (CW and CCW). This process meticulously characterizes the transducer’s linearity, hysteresis, and repeatability, forming the basis of its performance certification.

A standard calibration in a controlled lab doesn’t account for the environmental stresses of your application. Our enhanced service systematically addresses these factors before the final calibration.

1. Thermal Characterization (+75°F to +175°F)
We cycle your transducer through a range of elevated temperatures to verify its strain gage bridge performance. If any thermal-induced deviation is detected, we apply proprietary compensation techniques to bring it into compliance.

2. Rotational Speed Verification
Next, your transducer is run at its maximum rated speed for 30 minutes. This confirms that sustained rotation and dynamic effects do not introduce output variations that would be missed by a static test.

Only after the transducer’s performance is confirmed under thermal and rotational stress do we perform the final, official 10-point calibration. This ensures the data on your ISO 17025 accredited certificate reflects the transducer’s true performance in its intended environment.

For applications requiring a complete audit trail, we offer an As-Found/As-Left option. We perform an initial 10-point calibration as-received, then conduct the full environmental verification protocol. After any adjustments, we perform the final As-Left calibration, providing definitive, auditable proof of corrective action.

Related Calibration Services

Factory calibration is one part of our full range of torque transducer calibration services, which cover sensors from nearly any manufacturer from 10 ozf-in to 4,000,000 lbf-in. Pick the level of testing your application and quality requirements call for.

ISO/IEC 17025:2017 accreditation details: Review our NVLAP accreditation and scope.

Standard 10 point torque calibration: Bi-directional loading at ten points in CW and CCW for transducers of any make.

As found/as left torque calibration: Before and after data sets that document the effect of any repair or adjustment.

Mission-critical calibration services: As found/as left calibration paired with temperature and speed verification for Himmelstein transducers.

Want to learn more?

1-800-Measure or Contact Us

Contact Us

    Business Address

    2490 Pembroke Avenue
    Hoffman Estates, IL 60169